Download Pump Characteristics and Applications by Michael Volk PDF

By Michael Volk

During this moment variation of a book/CD-ROM reference for engineers, upkeep technicians, and plant operators, Volk, a specialist in pump platforms, provides fabric on contemporary recommendations, and expands fabric on elements that have been lined in basic terms in brief within the first version. there's new fabric on software program for the layout and research of pump piping s.

Show description

Read Online or Download Pump Characteristics and Applications PDF

Similar ventilation & air conditioning books

Heating, Ventilating and Air Conditioning Analysis and Design; 6 edition

According to the latest criteria from ASHRAE, the 6th variation presents entire and up to date assurance of all elements of heating, air flow, and air-con. you can find the most recent load calculation techniques, indoor air caliber strategies, and concerns relating to ozone depletion. additionally built-in in the course of the textual content are a variety of labored examples that sincerely enable you to practice the innovations in real looking situations.

Hydraulik der Gerinne und Gerinnebauwerke

Das vorliegende Buch basiert auf Unterlagen ffir den DVWK-Lehrgang "Stationare Gerinnehydraulik," den ich im April 1980 an der Universitat Karlsruhe zusammen mit den Kollegen Heinrich Dorer, Wilhelm Gehrig, Bruno Herrling, Franz Nest mann und Berthold Treiber durchffihrte. Obwohl ich stets vorhatte, die Lehr gangsunterlagen nach grfindlicher Uberarbeitung zu veroffentlichen, ist es doch dem beharrlichen Zuspruch von Hans Bischoff, Vorsitzender des DVWK-Fachaus schusses "Rohr- und Gerinnehydraulik," zu verdanken, daB dieses Vorhaben nun auch verwirklicht wurde.

Pump Characteristics and Applications

During this moment variation of a book/CD-ROM reference for engineers, upkeep technicians, and plant operators, Volk, a expert in pump structures, provides fabric on fresh suggestions, and expands fabric on elements that have been lined in basic terms in short within the first variation. there's new fabric on software program for the layout and research of pump piping s.

Discrete Optimization in Architecture: Building Envelope

This ebook explores the super modular structures that meet standards: they enable the production of structurally sound free-form buildings, and they're made out of as few kinds of modules as attainable. Divided into elements, it offers Pipe-Z (PZ) and Truss-Z (TZ) structures. PZ is extra basic and varieties spatial mathematical knots via assembling one kind of unit (PZM).

Extra info for Pump Characteristics and Applications

Example text

The parameters given for a particular pump type do not necessarily apply concurrently. As examples of this, the maximum flow listed is likely not available with the maximum pressure listed for that pump type. The maximum solids size listed is probably only able to be handled by the largest pumps of that type, and may be restricted below the maximum size shown in the table for solids of a particular shape, material, or concentration. D. pumps are self-priming to a certain degree. 1 are truly dry self-priming, that is, will prime on a lift when completely dry.

Three-screw pumps, on the other hand, generate some axial loads, although this is usually partially or fully balanced out. 21 Two-screw pump. 22 Three-screw pump.

Pumps. It is possible to handle lowviscosity liquids with centrifugal pumps. However, efficiency degrades rapidly as viscosity increases and there is an upper limit of viscosity above which it becomes impractical to consider centrifugal pumps due to the excessive waste of energy. Highly viscous liquids absolutely cannot be pumped with a centrifugal pump. ) For these liquids, some type of positive displacement pump may be the only practical solution. Most positive displacement pump types are inherently self-priming, meaning they can be located above the surface of the liquid being pumped without the necessity of the suction line being filled with liquid and the noncondensable gases in the suction line being removed before starting the pump.

Download PDF sample

Rated 4.27 of 5 – based on 5 votes